Fluorescence Emission of Pyrene in Surfactant Solutions
Please use this identifier to cite or link to this item:
http://hdl.handle.net/10347/17068
Files in this item
Metadata
Title: | Fluorescence Emission of Pyrene in Surfactant Solutions |
Author: | Piñeiro Maseda, Lucas Novo Rodríguez, María de la Merced Al-Soufi, Wajih |
Affiliation: | Universidade de Santiago de Compostela. Departamento de Química Física |
Subject: | Surfactants | Pyrene | Critical Micelle Concentration | Fluorescence | Kinetic Description | |
Date of Issue: | 2015 |
Publisher: | Elsevier |
Citation: | Piñeiro, L., Novo, M., & Al-Soufi, W. (2015). Fluorescence emission of pyrene in surfactant solutions. Advances In Colloid And Interface Science, 215, 1-12. doi: 10.1016/j.cis.2014.10.010 |
Abstract: | The systematic description of the complex photophysical behavior of pyrene in surfactant solutions in combination with a quantitative model for the surfactant concentrations reproduces with high accuracy the steady-state and the time resolved fluorescence intensity of pyrene in surfactant solutions near the cmc, both in the monomer and in the excimer emission bands. We present concise model equations that can be used for the analysis of the pyrene fluorescence intensity in order to estimate fundamental parameters of the pyrene-surfactant system, such as the binding equilibrium constant K of pyrene to a given surfactant micelle, the rate constant of excimer formation in micelles, and the equilibrium constant of pyrene-surfactant quenching. The values of the binding equilibrium constant KTX100 = 3300 103 M-1 and KSDS = 190 103 M-1 for Triton X-100 (TX100) and SDS micelles, respectively, show that the partition of pyrene between bulk water and micelles cannot be ignored, even at relatively high surfactant concentrations above the cmc. We apply the model to the determination of the cmc from the pyrene fluorescence intensity, especially from the intensity ratio at two vibronic bands in the monomer emission or from the ratio of excimer to monomer emission intensity. We relate the finite width of the transition region below and above the cmc with the observed changes in the pyrene fluorescence in this region |
Description: | This is the accepted manuscript of the following article: Piñeiro, L., Novo, M., & Al-Soufi, W. (2015). Fluorescence emission of pyrene in surfactant solutions. Advances In Colloid And Interface Science, 215, 1-12. doi: 10.1016/j.cis.2014.10.010.
© 2015 Elsevier B.V. This manuscript version is made available under the CC-BY-NC-ND 4.0 license (http://creativecommons.org/licenses/by-nc-nd/4.0/) |
Publisher version: | https://doi.org/10.1016/j.cis.2014.10.010 |
URI: | http://hdl.handle.net/10347/17068 |
DOI: | 10.1016/j.cis.2014.10.010 |
ISSN: | 0001-8686 |
Rights: | © 2015 Elsevier B.V. This manuscript version is made available under the CC-BY-NC-ND 4.0 license (http://creativecommons.org/licenses/by-nc-nd/4.0/) Attribution-NonCommercial-NoDerivatives 4.0 Internacional |
Collections
-
- QB-Artigos [21]
- QF-Artigos [112]
The following license files are associated with this item: